top of page

WINDPOSTS

Engineered Windpost Systems

BRAXIS is the KBS Design Solutions range of engineered windposts, providing lateral restraint to masonry walls. Each arrangement is developed around the wall geometry, applied loading and supporting structure, with coordinated post sections, connections and masonry ties. Our approach combines structural calculations, detailed CAD modelling and, where appropriate, Finite Element Analysis (FEA), helping develop practical solutions from design through to manufacture and installation.

L TYPE WINDPOST

Braxis BR1

An L-shaped section windpost, suited to details where one leg is incorporated into the masonry leaf. Dimensions, orientation, ties and end connections are determined for the project. Why it is used: BR1 provides a practical restraint arrangement where the wall build-up permits an angle section to engage with the masonry. Coordinate masonry continuity, ties and movement requirements.

C TYPE WINDPOST

Braxis BR2

A C-shaped channel section windpost. It can be detailed within a suitable cavity, with ties connecting masonry to the post and connections transferring lateral reactions to the primary structure. Why it is used: BR2 suits a channel profile within the available cavity and connection geometry. Cavity width, insulation, tie access and bending stiffness guide the final design.

SPINE WINDPOST

Braxis BR3

A flat plate spine post built into a vertical masonry joint, typically suited to single-leaf blockwork where the post should remain within the wall thickness. Plate depth, thickness, ties and end connections are designed for the project. Why it is used: BR3 suits an integrated spine arrangement providing restraint within the wall layout. Section geometry and stiffness are checked against project loads and serviceability criteria.

BOX SECTION WINDPOST

Braxis BR4 

A square or rectangular hollow section windpost, to suit the design requirements. Orientation, wall thickness and head/base connections are selected for the loading and available space. Why it is used: BR4 offers a compact closed-section arrangement where its stiffness and connection geometry suit the application, subject to engineering verification.

Why Windposts Are Required

Windposts provide intermediate lateral restraint where masonry panels need additional support against wind pressure, suction or other specified horizontal actions. Loads pass from masonry through ties into the post and its connections, then into the supporting structure. Spacing and section selection must be coordinated with masonry panel design.

Engineering and Technical Support

KBS develops the complete restraint arrangement: post selection, ties, head/base connections, fixing requirements and coordinated fabrication drawings. Calculations assess strength, stability and deflection. Where geometry or connection behaviour warrants it, FEA supports the assessment alongside conventional checks.

bottom of page