top of page

Design Considerations for Masonry Support Systems

KERNIX | Technical Masonry Support

01 | Why masonry support is required: Engineered support for modern masonry facades

Masonry support systems provide structural support to external brickwork and masonry façades, transferring the vertical dead loads of the supported masonry safely back to the building's primary structure.

​

In modern steel and concrete-framed buildings, the external masonry façade is frequently non-loadbearing and cannot rely on continuous support from the foundations. Dedicated masonry support systems are therefore required at designated levels to accommodate the building's structural arrangement and façade design.

​

Typically manufactured from stainless steel, masonry support systems comprise a series of brackets and continuous or segmented support angles fixed to the primary structure.

Typical applications

Multi-storey buildings • Brickwork above openings • Slab-edge support • Steel-framed structures • Concrete-framed structures • Project-specific façade interfaces

These systems allow masonry loads to be transferred through a defined structural load path while maintaining the required cavity dimensions, accommodating structural movements and supporting the architectural requirements of the façade.

​

Correctly designed masonry support is essential for maintaining the structural integrity, serviceability and long-term performance of masonry cladding.

KERNIX | Design Considerations

02 | Designed around the structure, not simply the brickwork

Every masonry support arrangement must be developed around the specific requirements of the building. Loads, cavity dimensions, supporting structure and façade geometry can vary considerably between projects.

​

Kernix systems are developed to accommodate these requirements through project-specific engineering, ensuring that the support arrangement is appropriate for the intended application.

- Masonry loading

The height, thickness, density and extent of the supported masonry determine the vertical loads imposed on the support system. These loads must be assessed alongside relevant eccentricities, construction tolerances and any additional actions applicable to the support arrangement.

- Cavity dimensions and bracket position

The distance between the masonry and the

supporting structure influences the bracket geometry, eccentric loading, bending moments and deflection. Support arrangements must accommodate the specified cavity construction, insulation, fire barriers and architectural detailing.

- Supporting structure and fixing design

Brackets must transfer their design actions safely

into the supporting concrete, steelwork or other approved structural substrate. Fixing selection considers the applied tension and shear forces, substrate properties, edge distances, embedment requirements and the available fixing zones.

- Movement and deflection

Differential movement between the masonry

façade and the primary structure must be considered. Support positions, movement joints, anticipated structural deflections and thermal or moisture-related masonry movements influence the detailing of the support system.

- Material specification and durability

Material grades and finishes are selected with consideration for environmental exposure, corrosion resistance, structural performance and the specified design life. Stainless steel is commonly used for concealed masonry support components because of its durability in cavity wall environments.

- Installation and buildability

Bracket locations, installation access, adjustment requirements, construction tolerances and the sequence of masonry installation must be incorporated into the design. Particular attention is required around corners, openings, movement joints and interfaces with other façade components.

KERNIX | The KBS engineering approach

03 | Engineering-led masonry support design

At KBS Design Solutions, our approach to masonry support extends beyond the selection of standard bracket sizes.

​

Through the Kernix range, we develop support arrangements around the specific loading, geometry and structural requirements of each project.

​

Our engineering workflow combines structural calculations, detailed 3D CAD modelling and, where appropriate, Finite Element Analysis (FEA) to assess the behaviour of individual components and complete support assemblies.

​

This approach enables us to investigate complex bracket configurations, evaluate alternative support arrangements and develop practical solutions for challenging façade interfaces.

DESIGN | ANALYSIS | VERIFICATION

- Structural calculations

Project-specific calculations establish

the design actions and assess the structural performance of the proposed masonry support system. These include appropriate checks on brackets, support angles, welds, connections and the forces transferred to the supporting structure.

Calculations are developed using relevant structural design standards, material properties and project-specific design criteria.

- 3D CAD Modelling

Detailed three-dimensional models

allow bracket geometry, support angle arrangements, fixing positions and structural interfaces to be developed and coordinated before manufacture.

This provides a clearer understanding of the proposed installation and enables potential clashes, restricted fixing zones and fabrication constraints to be identified during the design process.

- Finite Element Analysis (FEA)

Where conventional calculation

methods do not adequately represent complex component geometry or structural behaviour, FEA can provide additional insight into the performance of the proposed support arrangement.

Numerical analysis can be used to investigate stress distribution, local deformation, load transfer and the effects of geometric variations within the support assembly.

FEA results are interpreted alongside conventional engineering calculations, appropriate material models, boundary conditions and the relevant design criteria. Where required, physical testing or other suitable verification provides additional evidence of performance.

- Design for Manufacture

Engineering design and fabrication requirements are considered together, helping ensure that proposed support components can be manufactured accurately and installed efficiently.

Bracket geometry, material utilisation, welding, fabrication tolerances and fixing accessibility are considered as part of the design development process.

KERNIX | Why choose KBS Design Solutions?

04 | Technical support from concept to installation

The Kernix range combines engineered masonry support systems with the technical capabilities of KBS Design Solutions.

​

Rather than treating support brackets as isolated components, we consider the complete assembly, including the supported masonry, bracket geometry, structural fixings, supporting substrate and installation requirements.

​

Our design process allows us to develop standard or project-specific configurations, investigate alternative solutions and provide the technical information required for design coordination and manufacture.

Our technical capabilities

Project-specific structural calculations and design assessments.

​

Detailed 3D CAD modelling and technical drawings.

​

FEA-supported design development where appropriate.

​

Support bracket, angle and connection design.

​

Structural fixing selection and coordination.

​

Project-specific fabrication and installation detailing.

KERNIX | Technical Support

Have a masonry support requirement?

Speak to KBS Design Solutions about your project. Our team can review the proposed masonry arrangement, structural interfaces and design requirements to help develop an appropriate Kernix support solution.

Our objective is to provide a coordinated masonry support solution that meets the project's structural requirements while considering practical manufacture, installation and long-term performance.

bottom of page