Windpost Design Considerations
BRAXIS | Technical Windpost Design
A windpost must be designed as part of the complete masonry restraint system. The post, ties, end connections, anchors and supporting structure work together to transfer lateral actions while accommodating movement and construction requirements.
01 | Why Windposts Are Required
Windposts provide intermediate lateral restraint to masonry panels. Lateral actions pass from masonry through ties into the post, through its head/base connections and into the primary structure. Windposts provide lateral restraint rather than vertical masonry support, and do not automatically replace lintels or masonry support systems.
02 | Designed Around the Wall and Structure
Wind loading and exposure: Assess pressure and suction, project location, height, exposure, local effects, tributary wall area and other specified horizontal actions.
Wall geometry and post spacing: Consider panel height, length, openings, thickness, masonry properties and edge restraint. Spacing follows masonry panel design rather than a universal rule.
Section choice and orientation: BR1 L Type, BR2 C Type, BR3 Spine Post and BR4 Box Section. Select around available space, bending axis, eccentricities, stability and connection geometry.
Strength and deflection: Check resistance and serviceability against project criteria. Deflection can govern section selection; agree the applicable limits for the wall and connections.
Head/base connections and fixings: Establish restraint assumptions and reactions. Check plates, welds, bolts, anchors, substrate, edge distances and embedment. Coordinate frame verification with the structural engineer.
Movement and tolerances: Accommodate vertical frame and masonry movement and construction adjustment while maintaining lateral restraint. Slot direction and locking details must suit the intended load path.
Masonry ties and interfaces: Coordinate tie type, spacing, embedment and movement with insulation, cavity barriers, damp proofing, access, and thermal, fire and acoustic requirements.
Materials, durability and installation: Specify grade and finish for exposure and design life. Consider dissimilar metals, handling, access, installation sequence, tolerances and inspection.
03 | The KBS Engineering Approach
Structural calculations
Establish design actions and check post strength, stability, deflection, ties, connections and fixing reactions.
CAD modelling
Coordinate section geometry, tie positions, head/base details, fixing zones, tolerances and fabrication information.
Finite Element Analysis
Where geometry or connection behaviour warrants it, use justified boundary conditions and interpret results alongside conventional engineering checks.
Manufacture and installation
Develop buildable details with fabrication tolerances, welding requirements, adjustment, access and installation sequence considered together.
04 | Information for Your Windpost Enquiry
Provide project name and location; wall elevations and sections; panel heights, thicknesses and cavity dimensions; openings and proposed post positions; wind loads and design criteria; supporting steelwork or concrete; movement requirements; materials and finishes; programme.