KBS Technical Guidance
Fixings Design Considerations
A reliable fixing is the result of a design decision, not a product pick. This guide sets out the key questions to answer before you specify a mechanical or bonded anchor: what loads it must carry, what it is fixed into, which approval covers the use, and how it will be installed and checked on site. It is general guidance and does not replace a design by a competent engineer using the manufacturer's approved data.
1. Define the load path
Start by defining every action the fixture transfers to the base material: tension (pull-out), shear, and the bending that results when a load is applied at a distance from the base. Eccentricity from stand-off plates, brackets or cantilevered fixtures increases tension on some anchors in a group and can govern the design. Identify whether loads are static, cyclic, dynamic, seismic or safety-critical, apply the appropriate partial factors, and follow the load all the way into a structural element that can actually carry it.
Figure 1
Placeholder: tension N, shear V and bending from lever arm e on a fixed bracket.
2. Confirm the substrate
Anchor performance depends entirely on the base material. Confirm whether you are fixing into cracked or non-cracked concrete and its strength class, solid or hollow masonry, aerated block, timber or steel. Check for voids, render, insulation layers, reinforcement and embedded services. Where the substrate is unknown or variable, site pull-out testing is the reliable way to establish a design value.
3. Select a fixing for its approved use
Select a product whose European Technical Assessment (ETA) or equivalent approval covers the actual application: the base material, cracked or non-cracked condition, load type, fire or seismic performance where needed, and the installation conditions on site. Use only the design data published in that approval, and stay within its stated limits for diameter, embedment and temperature range.
4. Check resistance and anchor geometry
Design resistance is the lowest of several failure modes: steel failure, pull-out, concrete cone, splitting and pry-out in tension and shear, plus concrete edge failure. Deeper embedment generally raises cone resistance, while reduced spacing or edge distance causes failure zones to overlap and lowers capacity. Minimum member thickness prevents blow-out and splitting. Where tension and shear act together, check the combined interaction rather than each action in isolation.
- Effective embedment depth (hef) and drilled hole depth
- Anchor spacing (s) and edge distance (c), including minimum values
- Base member thickness (h) against the approved minimum
- Tension–shear interaction for combined loading
Figure 2
Placeholder: embedment hef, spacing s, edge distance c and member thickness h.
5. Consider durability and materials
Match the anchor material to the exposure. Zinc-plated steel suits dry internal conditions; hot-dip galvanised or stainless steel (A4 / 316) is typically needed externally, in damp or coastal environments, and wherever the fixing cannot be inspected or replaced. Avoid galvanic corrosion between dissimilar metals, and consider fire exposure and the service temperature range for bonded anchors.
6. Specify installation and inspection
Design values only apply when the anchor is installed exactly as the approval describes. Use the correct drilling method and bit diameter, drill to depth, and clean the hole thoroughly. For bonded anchors, follow the blow–brush–blow sequence, discard the first resin, inject from the bottom of the hole, and respect gel and cure times for the base material temperature. Apply the specified installation torque, and record and inspect installations, with proof testing where required.
Figure 3
Placeholder: drill, clean (blow–brush–blow), inject, insert, cure, then load.
Specification checklist
- Design loads defined: tension, shear, bending, load type and factors
- Base material identified and condition confirmed (cracked / non-cracked)
- Approved product with an ETA covering the intended use
- Embedment, spacing, edge distance and member thickness checked
- Combined tension–shear interaction verified
- Material and corrosion protection suited to exposure
- Installation method, torque and cure times stated on drawings
- Inspection, testing and record-keeping requirements set
Need help with a fixing specification?
Talk to the KBS team about product selection, approvals and installation requirements for your project.